1. Probable Cause / Reason:
• High overvoltage from impressed current systems causing coating failure.
• Sacrificial anodes in excessive quantity leading to disbondment.
• Incorrect cathodic protection system installation and poor monitoring.
• Incompatibility between the coating system and cathodic protection methods.
2. Correction / Repair:
• Identify and remove the affected coating areas down to sound material.
• Reclean and recoat the surface using compatible coating systems.
• Adjust cathodic protection settings to recommended levels.
• Revalidate system installation and optimize the number and placement of anodes.
3. Corrective Action / Prevention:
• Design and maintain a proper cathodic protection system with regular monitoring.
• Apply alkali-resistant and compatible coating systems.
• Use well-placed reference electrodes for effective voltage control.