1. Probable Cause / Reason:
• Low application temperature causing poor curing of the coating.
• Incompatibility with previous coatings or substrates.
• Aging of the coating or environmental factors.
• Excessive film thickness leading to stress and cracking.
2. Correction:
• Apply a thinner coat to reduce the risk of crazing.
• Use a slower-drying solvent to allow proper leveling and curing.
• Ensure that application and drying conditions match the coating system specifications.
• Check the compatibility of the coating with the substrate and previous layers.
3. Corrective Action / Prevention :
• Remove the affected coating and prepare the surface for re-coating.
• Reapply with a thinner layer and ensure correct environmental conditions.
• Verify that the coating system is compatible with the surface and previous coatings.