1. Probable Cause / Reason:
• Incorrect paint system or incompatible coatings for the substrate.
• Lack of or incorrect pretreatment for certain substrates, such as non-ferrous metals or galvanized surfaces.
• Poor application techniques, leading to improper bonding.
• Differential expansion and contraction of the substrate and paint, especially in materials like wood.
• Aging of the paint system, causing it to lose adhesion over time.
2. Correction:
• Ensure the use of the correct coating system designed for the specific substrate.
• Perform proper pretreatment and surface preparation, especially for challenging surfaces like galvanized metal or wood.
• Improve application techniques to ensure proper bonding and adhesion.
• Reapply with a more suitable coating system and consider a primer if needed.
3. Corrective Action / Prevention :
• Remove the flaked coating and prepare the surface for re-coating.
• Apply the correct coating system, ensuring proper bonding and adhesion.
• Regularly inspect the painted surface and ensure environmental conditions do not cause undue stress on the substrate.
BG GROUP OF PAINT AND COATING CONSULTANT
Email: support@bgcoating.com / inquiry.bggroup@gmail.com
Website: https://bgcoating.com
LinkedIn: https://www.linkedin.com/company/bggroupofpaintandcoatingconsultant/
Google My Business: https://maps.app.goo.gl/pUMmXu4D5tPhpnbh9
Booking Appointment: https://forms.gle/YaYPVNUT6ai3Ucuj9