1. Probable Cause / Reason:
• Overapplication of heavily pigmented primers
• Excessive coating thickness, especially in one coat
• Improper application of water-based or zinc-rich primers
• Use of incompatible or poorly formulated products
2. Correction:
• Remove the cracked coating by mechanical means
• Feather edges and clean the exposed surface
• Reapply the coating in multiple thin layers as per spec
• Ensure proper drying/curing time between coats
3. Corrective Action / Prevention:
• Apply coating within recommended thickness limits
• Follow proper application methods and spray techniques
• Use products suitable for the job and well-formulated