1. Probable Cause / Reason:
• Loss of adhesion due to surface contamination
• Incompatibility between primer and topcoat layers
• Moisture or oil presence during application
• Use of incorrect or poorly cured previous coating
2. Correction:
• Remove all loose or peeling coating by scraping or blasting
• Clean the surface thoroughly to remove all contaminants
• Apply suitable primer as per the system specification
• Recoat with compatible materials under proper conditions
3. Corrective Action / Prevention:
• Follow correct coating system and application sequence
• Ensure all surfaces are clean, dry, and contamination-free
• Confirm compatibility between all layers in the system